title: "How Much Office Space Does One Person Need in Germany?"
description: "German law sets a floor of 8 m² per work room plus 6 m² per further workstation. The harder question is how many workstations you need, and the attendance data answers that one."
canonical: "https://coworkingview.com/en/insights/office-space-per-employee-germany-asr-a1-2"
---

# How Much Office Space Does One Person Need in Germany?

German law sets a floor of 8 m² per work room plus 6 m² per further workstation. The harder question is how many workstations you need, and the attendance data answers that one.

## The short version

German workplace law tells you the smallest room you may legally put a desk in. It does not tell you how many desks to plan for — and that second number is where teams get their office wrong.

-   **The binding minimum is 8 m² for a work room, plus 6 m² for every further workstation.** That is a floor, not a target. It comes from [ASR A1.2](https://www.baua.de/DE/Angebote/Regelwerk/ASR/ASR-A1-2), the technical rule under the Arbeitsstättenverordnung.
-   **The realistic figure is 8–10 m² per workstation in a cell office and 12–15 m² in an open-plan one** — furniture and in-room circulation included. Open-plan is not more space-efficient per person. It is less.
-   **Every workstation also needs 1.5 m² of unobstructed movement area**, at least 1.00 m deep and wide, and 1.20 m wide where desks sit directly side by side. It may not overlap a walkway or another desk's movement area.
-   **German companies use 31% of their desks on an average day, 36% on the busiest one.** Sizing a room for headcount instead of attendance is how a 20-person team ends up planning 270 m² it will never fill.

## What the rule actually says

Two documents matter, and only one of them is law. The [Arbeitsstättenverordnung](https://www.gesetze-im-internet.de/arbst_ttv_2004/) (ArbStättV) is the regulation: it obliges the employer to provide work rooms with sufficient floor area, height and air volume. It gives almost no numbers. The numbers live in the _Technische Regeln für Arbeitsstätten_ — ASR A1.2, "Raumabmessungen und Bewegungsflächen", issued September 2013 and last amended in March 2022.

Here is the part everyone misquotes: **the ASR is not mandatory.** An employer may deviate from it. What the ASR gives you is _Vermutungswirkung_ — comply with it and the law presumes you have met your duty of care. Deviate, and the burden flips: you must demonstrate in your risk assessment (Gefährdungsbeurteilung) that your alternative reaches the same protection goals. In practice that is why almost everyone follows it.

Square metres per workstation under ASR A1.2Bar chart. Legal minimum 8 square metres for the room plus 6 for each further workstation; guide values 8 to 10 in a cell office and 12 to 15 in an open-plan office. 0 m² 4 m² 8 m² 12 m² 16 m² Legal minimum room floor area, first workstation 8 m² Each further workstation added to the room minimum 6 m² Cell office ASR guide value per workstation 8–10 m² Open-plan office ASR guide value per workstation 12–15 m² Orange = binding minimum · blue = ASR guide value, shown as a range · ASR A1.2, edition Sept 2013, last amended March 2022

The 8 m² is the minimum area of the **room**, not an allowance per person. A room with one workstation must be at least 8 m². Add a second workstation and the minimum becomes 14 m², a third makes it 20 m², and so on. Those are the bars you cannot go below.

The 8–10 and 12–15 figures are something different: _Richtwerte_, guide values, and they are per workstation including furniture and the circulation space inside the room. The gap between them is the counterintuitive part. Open-plan offices need **more** floor area per person, not less, because of the extra circulation and the acoustic and visual disruption the rule explicitly names. The efficiency argument for open-plan was never about square metres per head.

## Three numbers people forget

**Movement area: 1.5 m² per workstation.** It has to be one contiguous, unobstructed patch of floor, at least 1.00 m deep and wide for seated and standing work. Where several workstations sit directly next to one another, that widens to 1.20 m each. Crucially, movement areas may not overlap with each other, with walkways, escape routes, or with the footprint of equipment. This is the requirement that quietly kills the desk plan that looked fine in the CAD drawing.

**Air volume: 12 m³ per permanently present person** for mainly seated work — 15 m³ for mainly standing work, 18 m³ for heavy physical work, plus 10 m³ for each additional person who is in the room more than briefly. Combined with the ceiling-height rules below, this is what makes a converted basement fail even when its floor area passes.

**Ceiling height, by floor area:** at least 2.50 m up to 50 m², 2.75 m above 50 m², 3.00 m above 100 m², and 3.25 m above 2,000 m². It may be reduced by 0.25 m where the risk assessment finds no health concerns, but never below 2.50 m.

And one more from the neighbouring rule, ASR A1.8: a gangway to a personally assigned workstation needs 0.60 m; escape-route widths scale with how many people they serve — 0.875 m for up to 5, 1.00 m up to 20, 1.20 m up to 200.

## How the maths compounds

Plot the three numbers against a growing team and the shape of the problem appears.

Floor area a room needs as workstations are addedLine chart comparing the ASR legal minimum with the midpoints of the cell-office and open-plan guide values as team size grows. 0 70 140 210 280 2 4 6 8 10 15 20 Workstations in the room m² Legal minimum 122 m² Cell office (9 m²) 180 m² Open-plan (13.5 m²) 270 m² Legal minimum = 8 m² + 6 m² per further workstation · guide-value midpoints used for the other two lines

At twenty workstations, the legal floor is 122 m². The cell-office guide value lands at 180 m², and open-plan at 270 m². Same twenty people, more than double the floor area between the bottom and the top of that range — and none of those three lines includes a meeting room, a kitchen, a place to take a call, sanitary facilities, or storage. The ASR governs the work room. Everything else is on top.

This is also where the honest caveat belongs: guide values are guides. A well-designed 8 m² workstation with proper acoustics beats a badly laid-out 12 m² one, and the risk assessment, not the table, is what your Fachkraft für Arbeitssicherheit will actually ask about.

## The number the tables leave out

Everything above answers "how much space per desk". Nobody checks the more expensive question: **how many desks**.

The [deskbird Desk Sharing Index 2026](https://www.go-with-us.de/desk-sharing-index-deutsche-bueros-zu-gross-und-teuer/), published on 28 April 2026, tracked 31,458 users at 294 German companies across eight cities between October 2025 and March 2026. It found German offices running at **31% desk utilisation on an average day, 36% on Tuesdays and Wednesdays** — the peak. Germany averaged 1.31 office days per employee per week. Tuesday and Wednesday together took 47.7% of all bookings; Friday took 11.3%.

How many of a company's desks are actually in useBar chart applying measured German desk utilisation to teams of 5, 10, 20 and 50 desks. Desks provided Occupied on an average day (31%) Occupied on the busiest day (36%) 5 desks 1.6 / 1.8 empty at peak: 3.2 10 desks 3.1 / 3.6 empty at peak: 6.4 20 desks 6.2 / 7.2 empty at peak: 12.8 50 desks 15.5 / 18.0 empty at peak: 32.0 German desk utilisation: 31% average, 36% on Tuesdays and Wednesdays · deskbird Desk Sharing Index 2026

Read the bars carefully, because the honest version of this finding is narrower than the headline: those percentages are measured against desks companies already have, and companies that installed a booking system are self-selected toward hybrid work. It is not a claim that every German office is two-thirds empty. It is a claim that in the companies that measure, it is.

The pattern behind it is not softening. The [ifo Institute](https://www.ifo.de/pressemitteilung/2026-03-02/homeoffice-anteil-bleibt-stabil-bei-knapp-25) put the share of employees working at least partly from home at **24.3% in February 2026**, and has recorded roughly a quarter since 2022 — peak 32.3% in March 2021, trough 23.4% in August 2024. There is no return-to-office wave in the German data. Among IT service providers the home-office share is 76.4%, among management consultants 67.6%.

[CBRE's 2026 occupier survey](https://www.cbre.de/press-releases/cbre-studie-unternehmen-bauen-buros-fur-direkten-austausch-um-sozialflachen-wachsen-um-120-prozent) shows companies acting on it: fixed assigned desks fell from 83% of workplaces in 2021 to 55%, while desk-sharing models rose from 12% to 36%. Most companies that share stay conservative, at 1.01 to 1.49 people per desk.

## So which number do you plan against?

Not headcount, and not average attendance either. **Plan against the peak you are willing to accommodate**, then decide what happens on the days it is exceeded.

A worked example, using the German averages above rather than any assumption of ours. A twenty-person team, hybrid, with Tuesday and Wednesday as its anchor days:

Sizing basis

Workstations

Cell office at 9 m²

Open-plan at 13.5 m²

One desk per person

20

180 m²

270 m²

Sharing ratio 1.3 (CBRE median band)

16

144 m²

216 m²

Peak-day occupancy (36%)

8

72 m²

108 m²

Average-day occupancy (31%)

7

63 m²

95 m²

The spread between the top row and the third is not a rounding difference. It is the difference between a floor and a room.

Two warnings before anyone takes the bottom row seriously. First, 36% is a **measured average across many companies**, not your team's peak — a twelve-person all-hands on a Wednesday is your real constraint, and no average will warn you about it. Second, the legal minimum applies to whatever you build: eight workstations still means a room of at least 50 m², regardless of how empty it is on Friday.

## What this means if you don't want to plan a floor plan

The ASR obligations sit with the employer, but the _floor plan_ problem — laying out movement areas that don't overlap, keeping gangways clear, hitting the ceiling-height and air-volume thresholds — is only yours if you are fitting out a shell yourself.

In a serviced or flexible office, the operator has already resolved room dimensions, circulation and escape routes for the space they hand you, and you scale by adding or removing seats rather than by re-planning a room. That changes the question from "how many square metres do we lease" to "how many seats do we hold, and what do we do on peak days" — which, given the numbers above, is the question that actually decides whether an office fits.

It also moves the meeting-room maths off your floor plate. Across the 192 German locations in the CoworkingView index, spread over 49 cities, 97% list bookable meeting rooms and 93% a lounge area — shared space that exists for your Wednesday peak without sitting empty on your Friday.

If you want to see what is available in a specific city, the [Germany overview](https://coworkingview.com/en/coworking/germany) lists every location we track, and each city page — [Berlin](https://coworkingview.com/en/coworking/berlin), [Munich](https://coworkingview.com/en/coworking/munich), [Hamburg](https://coworkingview.com/en/coworking/hamburg), [Frankfurt](https://coworkingview.com/en/coworking/frankfurt) — breaks down by district and by what each space includes.

## A checklist before you sign or build

-   **Count workstations, not people.** The legal minimum keys off the number of workstations in the room: 8 m² + 6 m² each thereafter.
-   **Draw the movement areas before the desks.** 1.5 m² each, 1.00 m minimum depth and width, 1.20 m where desks adjoin, no overlap with walkways or each other.
-   **Check the ceiling against the floor area**, not against how the room feels: 2.50 / 2.75 / 3.00 / 3.25 m thresholds at 50, 100 and 2,000 m².
-   **Do the air-volume sum** for everyone permanently in the room: 12 m³ each seated, plus 10 m³ per additional regular occupant.
-   **Ask what happens on Tuesday and Wednesday**, not on an average day. Your peak is roughly your anchor-day attendance, and that is what people will remember.
-   **Write it into the Gefährdungsbeurteilung.** If you deviate from the ASR, that document is where you show the protection goals are still met — it is the only thing that carries any weight in an inspection.

Related reading: [How Germany's home office law is reshaping workspace demand](https://coworkingview.com/en/insights/the-shift-in-german-workspace-how-germanys-home-office-law-affects-coworking-demand) · [Flexible office space for companies in Germany](https://coworkingview.com/en/insights/flexible-office-space-for-companies-in-germany-the-future-of-workspace-agility) · [Setting up a branch office in Germany](https://coworkingview.com/en/insights/setting-up-branch-office-germany-workspace) · [Workspace glossary](https://coworkingview.com/en/glossary)

## Sources

-   BAuA, _ASR A1.2 — Raumabmessungen und Bewegungsflächen_, edition September 2013 (GMBl 2013 p. 910), last amended March 2022 (GMBl 2022 p. 241) — [baua.de](https://www.baua.de/DE/Angebote/Regelwerk/ASR/ASR-A1-2)
-   _Verordnung über Arbeitsstätten_ (ArbStättV) — [gesetze-im-internet.de](https://www.gesetze-im-internet.de/arbst_ttv_2004/)
-   BAuA, _ASR A1.8 — Verkehrswege_ (gangway and escape-route widths) — [baua.de](https://www.baua.de/DE/Angebote/Regelwerk/ASR/ASR-A1-8)
-   deskbird, _Desk Sharing Index 2026_, published 28 April 2026 — 31,458 users, 294 German companies, eight cities, October 2025–March 2026 — [summary and figures](https://www.go-with-us.de/desk-sharing-index-deutsche-bueros-zu-gross-und-teuer/)
-   ifo Institut, _Homeoffice-Anteil bleibt stabil bei knapp 25 %_, 2 March 2026 — [ifo.de](https://www.ifo.de/pressemitteilung/2026-03-02/homeoffice-anteil-bleibt-stabil-bei-knapp-25)
-   CBRE Germany, occupier survey 2026 — [cbre.de](https://www.cbre.de/press-releases/cbre-studie-unternehmen-bauen-buros-fur-direkten-austausch-um-sozialflachen-wachsen-um-120-prozent)
-   Amenity coverage across 192 German locations: CoworkingView index, 21 August 2026

This article summarises German workplace rules for planning purposes and is not legal advice. The Gefährdungsbeurteilung for your specific space is what determines compliance; involve your Fachkraft für Arbeitssicherheit before you commit to a layout.

## FAQ

**How much office space does one employee need in Germany?**
The binding minimum under ASR A1.2 is 8 m² of room floor area for the first workstation plus at least 6 m² for every further workstation. The realistic guide values are 8–10 m² per workstation in a cell office and 12–15 m² in an open-plan office, including furniture and the circulation space inside the room.

**Is ASR A1.2 legally binding?**
No. The Arbeitsstättenverordnung is the law; ASR A1.2 is the technical rule that fills in the numbers. Following it gives you Vermutungswirkung, meaning compliance is presumed. An employer may deviate, but then has to demonstrate in the Gefährdungsbeurteilung that the alternative reaches the same protection goals.

**Do open-plan offices need more or less space per person than cell offices?**
More. ASR A1.2 sets 8–10 m² per workstation for cell offices and 12–15 m² for open-plan ones, because of the higher circulation requirement and the acoustic and visual disruption the rule explicitly names.

**How much movement area does a workstation need?**
At least 1.5 m² of contiguous, unobstructed floor, a minimum of 1.00 m deep and wide for seated and standing work, widening to 1.20 m where workstations sit directly next to one another. Movement areas may not overlap with each other, with walkways, escape routes, or with equipment footprints.

**What ceiling height does a German office need?**
At least 2.50 m for rooms up to 50 m², 2.75 m above 50 m², 3.00 m above 100 m², and 3.25 m above 2,000 m². The figure may be reduced by 0.25 m where the risk assessment finds no health concerns, but never below 2.50 m.

**How many desks does a hybrid team in Germany actually need?**
Fewer than its headcount. The deskbird Desk Sharing Index 2026 measured 31% desk utilisation on an average day in German companies and 36% on Tuesdays and Wednesdays, the peak. CBRE's 2026 survey found most desk-sharing companies at 1.01 to 1.49 people per desk. Plan against the peak you want to accommodate, not against headcount.

Source: https://coworkingview.com/en/insights/office-space-per-employee-germany-asr-a1-2